3. Connect End A of the serial RS-422 cable to the correct connector on the control PCB in the plasma
power supply:
For cutting systems with multiple plasma power supplies, use the top connector (J12) for the
CNC. Use the bottom connector (J13) to connect to the next plasma power supply.
For cutting systems with one plasma power supply, you can use either connector to connect to
the CNC.
4. Connect End B of the cable to the CNC.
5. If you want to operate the cutting system, continue with the next step.
If you want to only monitor with RS-422 serial, you are done.
6. Connect to the plasma power supply with discrete on page 162.
Figure 43 - Connect the serial RS-422 cable to the plasma power supply