WARNING
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that can seriously
injure or kill you. Even if the plasma power supply is turned OFF, you can still get
a serious electric shock if the plasma power supply remains connected to an
electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when the plasma
power supply remains connected to an electric power source and the outer cover
or panels are removed.
1. Remove the power from the cutting system:
a. Set the line-disconnect switch to the OFF position.
b. Make sure that the power-indicator LED on the plasma power supply is not illuminated.
2. Remove the control-side panel of the plasma power supply.
3. On the main control PCB, set position 4 on DIP switch S3 to the ON position.
This disables the wireless.
4. Install the control-side panel of the plasma power supply.
Connect for Communication
4
186