You can see the coolant level from the view window on the front of the cooler as you add the coolant.
CAUTION
WET FLOOR
If you put too much coolant in the reservoir, the coolant can go through an
overflow tube and come out at the bottom of the cooler. Coolant can cause
floors to become slippery.
Be careful not to put too much coolant in the reservoir.
5. Install the cap onto the coolant reservoir.
6. Supply power to the cutting system:
a. Set the line-disconnect switch to the ON position.
b. Make sure that the remote on-off switch is in the ON position.
c. Make sure that the green power-indicator LED is illuminated on the cooler.
7. Use the CNC or XPR web interface to send a process to the plasma power supply and start the
coolant pump.
□
When you send a process, the gases start to flow, and after a few seconds the coolant pump
starts.
Coolant Installation
5
212
811530 Instruction Manual XPR460