For information about how to select consumables for your cutting or marking applications, refer to the
XPR Cut Charts Instruction Manual (809830).
1. Remove the power from the cutting system:
a. Set the line-disconnect switch to the OFF position.
b. Make sure that the power-indicator LED is not illuminated on the plasma power supply or
other system components.
2. Loosen the torch coupler nut to release the torch from the torch receptacle.
The torch and consumables can be hot. Put on gloves to prevent burns.
3. Put the torch and torch receptacle on a surface that is:
Clean
Dry
Oil-free
4. Remove the consumables as shown.
5. Use the consumable tool to turn the electrode counterclockwise.
6. Hold the tool tightly and pull straight out to correctly remove the electrode.
7. Put the consumables on a surface that is:
Clean
Dry
Oil-free