Use a container that holds the approximate total coolant
volume for your cutting system.
b. Attach compressed air (no more than 6.89 bar/100 psi) to the disconnected end of the coolant
supply hose (green band).
c. For approximately 3 minutes, inject compressed air into the coolant supply hose fitting to force
coolant to flow out of the coolant return hose (red band) into an empty container.
d. After 3 minutes, look for coolant that flows out of the coolant return hose (red band).
e. Do the previous step again until coolant flow from the coolant return hose (red band) stops.
f. When the coolant flow from the coolant return hose (red band) stops, connect the two hoses
to the rear of the plasma power supply.