Page 2
Does the 24 VDC supply in the gas connect
console measure 24 VDC on the output?
Do a cycle of remote on/off, and look for
a 24 VDC supply again.
Go to page 3.
No
Yes
Does the 24 VDC supply now measure
24 VDC on the output?
Set the XPR 3-phase to OFF, and
disconnect the 24 V output leads.
Try to send the process again.
No
Yes
Set the XPR back to ON, and
measure 24 VDC output.
Does the 24 VDC supply now measure
24 VDC on the output?
Replace the 24 VDC power
supply (229640).
There is a 24 VDC system short.
Speak to Technical Service.
Yes
No
Diagnostics and Troubleshooting
8
362
811530 Instruction Manual XPR460