Table 36 - Valve states by process ID (continued)
Process IDs: 8007, 8010
Block type Gas V1 V4 V5 V6 V7 V8 V9 V10 V11 V12 B1 B2 B3 B4 B5 B8 B9 B10
Preflow N
2
/Air Off Off Off On Off Off On Off Off Off On On Off Off Off Off Off Off
Cutflow N
2
/Air Off Off Off On Off Off On Off Off Off On On Off Off Off Off Off Off
Piercing N
2
/Air Off Off Off On Off Off On Off Off Off On On Off Off Off Off Off Off
Process IDs: 9007, 9019
Block type Gas V1 V4 V5 V6 V7 V8 V9 V10 V11 V12 B1 B2 B3 B4 B5 B8 B9 B10
Preflow Ar/Air Off Off Off On Off On On Off On Off On On Off Off Off Off Off Off
Cutflow Ar/Air Off Off Off On Off On On Off On Off On On Off Off Off Off Off Off
Piercing Ar/Air Off Off Off On Off On On Off On Off On On Off Off Off Off Off Off
Process IDs: 9008
Block type Gas V1 V4 V5 V6 V7 V8 V9 V10 V11 V12 B1 B2 B3 B4 B5 B8 B9 B10
Preflow Ar/Air Off Off Off On Off On Off Off Off Off On On Off Off Off Off Off Off
Cutflow Ar/Air Off Off Off On Off On Off Off Off Off On On Off Off Off Off Off Off
Piercing Ar/N
2
Off Off On Off Off On Off Off Off Off On On Off Off Off Off Off Off
449
811530Instruction ManualXPR460
Wiring Diagrams
10