Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
3123 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Due to the multi-adapter bridge configuration the IOA with the
load source device for the secondary partition does not belong to the IOP it
was assigned to when the secondary partition was configured.
Contact your next level of support.
LPARSUP
3125 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information on logical partitions. See
the iSeries Service Functions information.
Primary partition main store utilization problem. The Primary partition
code could not obtain a segment of main storage within the Primary
partitions main store to use for managing the creation of a secondary
partition.
LPARCFG
3128 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. An unexpected failure return code was returned when
attempting to query the IOA slots that are assigned to an IOP.
FI00099
3130 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. If word 3 is zero, then this SRC is informational and can be
ignored.
Otherwise there is a problem in the Primary partition. A non-zero bus
number has no associated bus object.
Contact your next level of support.
LPARSUP
3135 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. An unknown bus type was detected.
FI00099
3140 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. The load-source IOP is not owned by the secondary partition.
This is a configuration problem in the secondary partition. Have the
customer re-configure the partition to have the intended load-source IOP.
If there is not a configuration problem then contact your next level of
support.
LPARSUP
3200 A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information about logical partitions.
See the iSeries Service Functions information.
Look for an SRC in the Service Action Log of the Primary partition logged
at the time the secondary partition was IPLing. Use the new SRC and go to
Chapter 2. Unit Reference Codes on page 59.
FI00098
FI00096
B2xx
210
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals