Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item Location
1104 Failure reading media or not install media
Determine that correct install media is loaded. If correct install
media is installed, media could be corrupt. Obtain another copy
of the install media and reattempt the install. If the install still
fails, contact your service representative.
1201 Critical database segment could not be created
Perform “LIC-PIP8” on page 349.
AJDG301
1204 Error in constraint enforcement
Perform “LIC-PIP8” on page 349.
AJDG301
1210 Object not found in the in-use table
Perform “LIC-PIP8” on page 349.
AJDG301
1215 Error in critical code sequence
Perform “LIC-PIP8” on page 349.
AJDG301
1219 A back leveled driver has been detected
Perform “LIC-PIP8” on page 349.
AJDG301
1604 Not able to create APPN task
An error occurred during task creation which requires a power
off of the system.
Perform “LIC-PIP8” on page 349.
AJDG301
1724 An attempt to create a segment failed
The create could fail for two reasons:
v A code problem
Perform “LIC-PIP8” on page 349.
v No free auxiliary storage on the system
Add additional DASD if the create failed because no
auxiliary storage was available.
AJDG301
1730 An IPL is needed to restore system performance
Licensed Internal Code has detected a condition that is
impacting system performance. System operation can continue,
but system performance may be noticeably reduced until the
next IPL.
Look at the Product Activity Log entry, and find the value at
offset x’000180’. If the value equals x’00000122’, the error was
caused by too much processor memory being installed.
For more information, contact IBM Service Support.
GG3PL01
3000 Logical partition service function Main Storage Dump.
Copy the current main storage dump to media. For more
information on how to copy a Main Storage Dump, refer to the
iSeries Service Functions Information (see ″Copying a Main
Storage Dump″ under ″Working with Storage Dumps″).
AJDG301
B6xx (including A6xx)
Chapter 2. Unit Reference Codes 245