Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item Location
7004 TCP/IP informational error
This reference code is logged when the TCP/IP Attribute “Log
Protocol Errors” is set, and the TCP/IP System LIC “silently
discards” an inbound datagram. “Silently discard” is defined to
mean discard the received datagram without reporting an error
to the originating host device. Examples of such datagrams are
those with checksums or destination addresses which are not
valid.
This reference code is for information only. Normally no action
should be taken as a result of this reference code. It is
generated in order to assist with remote device or TCP/IP
network problem determination.
7055 Statistics were logged, no service action required
This reference code is logged for information only.
7100 APPN session initiation attempt has timed out
This reference code is used to indicate that LIC timed out on a
request to initiate a session.
The user must run problem analysis for this reference code. If
this indicates a software problem, the user should dial IBM
Software Support for assistance.
The Problem Determination Procedure (PDP) will indicate
whether the original timeout condition still exists and what the
corrective actions should be.
AJDG301
GG3PL03
GG3PL01
GG3PL02
7101 APPN session initiation attempt has failed
This reference code is used to indicate that LIC attempted to
satisfy a session initiation request, but some failure condition
was detected by LIC. The failure condition could be a
configuration or operational problem in the network.
The user must run problem analysis for this reference code. If
this indicates a software problem, the user should dial IBM
Software Support for assistance.
The Problem Determination Procedure (PDP) will indicate
whether the original timeout condition still exists and what the
corrective actions should be.
GG3PL04
GG3PL05
GG3PL06
AJDG301
7102 APPN CP-CP session ended.
7201 A utility failure occurred.
This reference code is for information only. The Uninterruptible
Power System (UPS) is reporting a utility failure.
7202 Utility power restored.
This reference code is for information only. The Uninterruptible
Power System (UPS) is reporting that utility power has been
restored.
7203 A battery low condition was detected.
This reference code is for information only. The Uninterruptible
Power System (UPS) is reporting a battery low condition.
B6xx (including A6xx)
272
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1