c. From the ″Recover configuration data″ screen select option ″Accept load source
disk unit″.
This ends the procedure.
14. The reporting partition is a secondary partition.
Since the last IPL of the reporting partition, have one of the following
occurred:
v Has the Primary partition time/date been moved backward to a time/date
earlier than the previous setting?
v Has the system serial number been changed?
v Was the load source disk unit in this seconday partition, replaced
intentionally with a load source from another system or another partition
from the same system?
Yes No
↓ Contact your next level of support.
This ends the procedure.
15. Use the ″Accept load source disk unit″ option to accept the new load source into
the current partition.
a. Go to SST/DST in the current partition and select option ″Work with system
partitions″.
b. From the ″Work with system partitions″ screen select option ″Recover
configuration data″.
c. From the ″Recover configuration data″ screen select option ″Accept load source
disk unit″.
This ends the procedure.
16. One or more B600 5311 SRCs have been logged in the same partition.
Do all of the B600 5311 errors have a resource which is a non-configured disk
unit in the partition?
Note: To determine if a disk unit is a non-configured disk unit, refer to the
″Work with disk unit options″ section in the ″DST options″ section of
the ″DST chapter″ in the iSeries Service Functions information.
Yes No
↓ None of the conditions in this procedure have been met, call your next
level of support.
This ends the procedure.
17. Were any disk unit resources associated with the B600 5311 SRCs added to the
partition, since the last IPL of this partition?
No Yes
↓ Use the ″Clear non-configured disk unit configuration data″ option to clear
old configuration data from each new disk unit device.
a. Go to SST/DST in the partition and select option ″Work with system
partitions″.
b. From ″Work with system partitions″ screen select ″Recover
configuration data″.
c. From the ″Recover configuration data″ screen select option ″Clear
non-configured disk unit configuration data″.
LPAR PIPs
378
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1