If you want to continue with this repair option, go to step 10 of this
procedure.
6. Perform the following:
a. Install the missing devices in the correct locations in the system (see
Chapter 4. Removal and Installation Procedures on page 617).
b. Power on the system (see Powering On and Powering Off the System and
Logical Partitions on page 922).
Does the IPL complete successfully?
No Yes
This ends the procedure.
7. Go to Starting Point for All Problems on page 4 to correct the problem.
This ends the procedure.
8. You have chosen to stop the disk array that contains the missing devices.
Attention: Customer data may be lost.
Perform the following:
a. If you are not already using dedicated service tools, perform an IPL to
DST (see Dedicated Service Tools (DST) in the iSeries Service Functions
information).
If you cannot perform a type A or B IPL, perform a type D IPL from
removable media.
b. Select the Work with disk units option.
Did you get to DST with a Type D IPL?
Yes No
1) Select the Work with disk configuration option.
2) Select the Work with device parity protection option.
Then continue with the next step of this procedure.
c. Select the Stop device parity protection option.
d. Follow the on-line instructions to stop device parity protection.
e. Perform an IPL from disk.
Does the IPL complete successfully?
No Yes
This ends the procedure.
9. Go to Starting Point for All Problems on page 4 to correct the problem.
This ends the procedure.
10. You have chosen to initialize and format the remaining members of the disk
array.
Attention: Customer data will be lost.
Perform the following:
a. If you are not already using dedicated service tools, perform an IPL to
DST (see Dedicated Service Tools (DST) in the iSeries Service Functions
information).
If you cannot perform a type A or B IPL, perform a type D IPL from
removable media.
SDIOP PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 419

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals