Failing Item Code
Description/Action If only a type number is listed, go to the Type, Model, and Part
Number list on page 885 to determine the part number.
FI00096 FI00096 indicates that the IOP attached to the load-source device is the failing item.
Note: Determine if the system has logical partitions. Go to Determining if the System Has
Logical Partitions on page 943, before continuing with this procedure.
1. Verify that the IPL type is correct:
v For a failing logical partition, other than the Primary partition, on systems with
multiple logical partitions, go to the Work with partition status screen and
determine the active IPL type (source).
v For a failing Primary partition or for systems with only one partition select function
01 (Select IPL) on the control panel to display the active IPL type.
2. The failing CFIOP or IOP may have a removable storage I/O adapter FRU. Replace the
storage IOA first using the STORIOA symbolic FRU. To locate the load source for a
system that does not have multiple partitions see Determining the Load Source Disk
and Alternate IPL Device on page 944. To locate the load source for the Primary
partition on a system that has multiple partitions see Determining the Load Source
Disk and Alternate IPL Device on page 944. To locate the load-source for a secondary
partition see iSeries Service Functions.
FI00098 FI00098 indicates that the load-source disk device is the failing item.
Note: Determine if the system has logical partitions. Go to Determining if the System Has
Logical Partitions on page 943, before continuing with this procedure.
Determine the disk unit 1 type number. It is printed on a label on the front of the system
frame.
If the system does not have a label that identifies the disk unit type, you can determine the
part number of the disk unit by looking at a label located on the disk unit. You must
remove the disk unit to see this label.
Exchange the disk drive and logic card for the disk unit type you have (see Type, Model,
and Part Number list on page 885).
To locate the load source for a system that does not have multiple partitions see
Determining the Load Source Disk and Alternate IPL Device on page 944. To locate the
load source for the Primary partition on a system that has multiple partitions see
Determining the Load Source Disk and Alternate IPL Device on page 944. To locate the
load-source for a secondary partition see iSeries Service Functions.
FI00099 FI00099 indicates that the Licensed Internal Code failed or responded in an unpredictable
way.
Ask your next level of support for assistance.
FI00121 FI00121 indicates that any tape or optical storage device attached to the I/O (SCSI) bus of
this IOP may be the failing item.
Use the device type to determine the part.
FI00122 FI00122 indicates that a reserved IOA port on the IOP is the failing item.
If the IOP is type 2624, the failing item is type 6146 IOA.
FI00123 See the symbolic FRU DEVTERM on page 525.
FI00124 FI00124 indicates that the control panel is the failing item.
For part number information, see 9251 and 507x, 508x Expansion Tower(s) Control Panel in
the parts section of Migrated Expansion Tower Problem Analysis, Repair and Parts.
Failing Items
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 481

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals