Replace the following using the appropriate Locations and Failing
Items Table for the Model/Feature Code you are working on (see
either Table 41 on page 710, Table 42 on page 720, Locations FC
5074 I/O Tower on page 736, or Locations FC 5079 I/O Tower
on page 747):
For FC 9074, 9079, 5074, 5079:
v NB1 Control Panel
v CB1 Tower Card
v PWR60 Power Distribution Board (PB1) to Device Board (DB3)
v SIG63 Control Panel (NB1) to Device Board (DB3)
This ends the procedure.
5. Replace the following (see Locations FC 5078, 0578 PCI Expansion Unit
on page 743):
For SRC 3101 or 3115:
v NB1 Control Panel
v CB1 Tower Card
This ends the procedure.
For SRC 3105 or 3116:
v BB1 part 11K1107 (Fan Contoller Asm.)
v CB1 - Tower Card
This ends the procedure.
6. Is the SRC 3102?
No Yes
Replace the following using the appropriate Locations and Failing
Items Table for the Model/Feature Code you are working on (see
either Table 41 on page 710, Table 42 on page 720, Locations FC
5074 I/O Tower on page 736, Locations FC 5079 I/O Tower on
page 747, or Locations FC 5078, 0578 PCI Expansion Unit on
page 743):
v C08 HSL I/O bridge
v CB1 Tower Card
This ends the procedure.
7. Is the SRC 3103?
No Yes
Replace the following using the appropriate Locations and Failing
Items Table for the Model/Feature Code you are working on (see
either Table 41 on page 710, Table 42 on page 720, Locations FC
5074 I/O Tower on page 736, Locations FC 5079 I/O Tower on
page 747, or Locations FC 5078, 0578 PCI Expansion Unit on
page 743):
For FC 9074, FC 9079 or FC 5074/5079:
v DB1 Device Board
v DB2 Device Board
v DB3 Device Board
v CB1 Tower Card
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 547