Interroll Drum motor DM series connecting cable
24 Version 2.0 (06/2018) en
Translation of original instruction manual
Removing the connecting cable
DANGER
Danger - electrocution
4 Only perform maintenance and repair work after you have switched off the power.
4 Faults on electrical equipment may be removed only by a trained electrician!
NOTICE
Improper assembly
Damage to the motor
4 During disassembly, ensure that the grease at the seals is not removed.
4 Protect the socket in the motor and the cable plug against contamination.
Required tools:
Open-end wrench, 14 mm WAF
Open-end wrench, 20 mm WAF

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interroll DM series and is the answer not in the manual?

Interroll DM series Specifications

General IconGeneral
Protection ClassIP54
Operating ModeS1 (Continuous Duty)
TypeBrushless
Storage Temperature-40°C to +70°C
Rated Voltage24 V DC