EasyManua.ls Logo

iXBlue GAPS - Page 181

iXBlue GAPS
232 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GAPS - User Guide
H.4 Hoisting System
The hoisting system uses a PMEVL MEA datagram type.
$PMEVL,0,MEA,type,%e
1
e
2
e
3
e
4
e
5
*ck<CR> <LF>
$PMEVL,0,MEA,type,%e
1
e
2
e
3
e
4
e
5
<CR> <LF> (
1
)
$PMEVL,0,MEA,10,%01010<CR> <LF> (
2
)
Field Range Description
type 0 to 10 10 : Hoisting System state
e
1
e
2
e
3
e
4
e
5
0,1
0,1
0,1
0,1
0,1
High position (1: yes, 0: no)
Low position (1: yes, 0: no)
Door closed (1: yes, 0: no)
Door opened (1: yes, 0: no)
System default (1: yes, 0: no)
ck 00 to FF Checksum NMEA 183 of datagram
(
1
) When the computation of the checksum is not possible, it is OK to omit the checksum, in
this case, the [*] must be omitted as well.
(
2
) Example of a datagram from a fully deployed hoisting system without checksum
MU-GAPS-AN-005-H - November 2019 181

Table of Contents

Other manuals for iXBlue GAPS