Uptime 3 hours, 27 minutes, 27 seconds
Load averages: 1 minute 5 minute 15 minute
0.44 0.16 0.06
•
To check the status of the SCB, issue the show chassis environment cb command. The output is similar
to the following:
user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 40 degrees C / 104 degrees F
Power 1
1.2 V 1208 mV
1.5 V 1521 mV
1.8 V 1807 mV
2.5 V 2507 mV
3.3 V 3319 mV
5.0 V 5033 mV
12.0 V 12142 mV
1.25 V 1243 mV
3.3 V SM3 3312 mV
5 V RE 5059 mV
12 V RE 11968 mV
Power 2
11.3 V bias PEM 11253 mV
4.6 V bias MidPlane 4814 mV
11.3 V bias FPD 11234 mV
11.3 V bias POE 0 11176 mV
11.3 V bias POE 1 11292 mV
Bus Revision 42
FPGA Revision 1
To check the status of a specific SCB, issue the show chassis environment cb node slot command, for
example, show chassis environment cb node 0.
For more information about using the CLI, see the CLI Explorer.