Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 23 0 2048 19 14
1 Offline ---Offlined by cli command---
2 Online 49 37 0 1024 14 25
The command output indicates the MPC is offline.
Bring the MPC online for the first time by using the following CLI command:
user@host> request chassis fpc slot 1 online
node0:
--------------------------------------------------------------------------
Online initiated, use "show chassis fpc" to verify
Verify that the MPC is online:
user@host> request chassis fpc slot 1 online node 0
node0:
--------------------------------------------------------------------------
FPC 1 already online
The command output indicates the MPC is online.
Confirm that the MPC in the chassis is online:
user@host> show chassis fpc
node0:
--------------------------------------------------------------------------
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 6 0 2048 19 14
1 Online 44 11 0 1024 23 29
2 Online 49 22 0 1024 14 25
SRX5400 Services Gateway Craft Interface Alarm Relay Contacts
The craft interface has two alarm relay contacts for connecting the device to external alarm devices (see
Figure 5 on page 40). Whenever a system condition triggers either the major or minor alarm on the craft
39