node0:
--------------------------------------------------------------------------
Offline initiated, use "show chassis fpc" to verify
{primary:node0}
user@host> show chassis fpc
node0:
--------------------------------------------------------------------------
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 35 7 0 1024 13 25
1 Online 46 4 0 1024 13 25
2 Offline ---Offlined by cli command---
After pushing MPC online button:
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 34 5 0 1024 13 25
1 Online 46 3 0 1024 13 25
2 Offline ---Offlined by button press---
To bring an MPC back online using the Online/Offline buttons:
1. Press and hold the corresponding card’s Online/Offline button on slot 1 on the craft interface. The
green OK/FAIL LED next to the button and the MPC’s LED begins to blink. Hold until both the button’s
LED and the MPC’s LED are green and steady.
2. Issue the CLI show chassis fpc command to check the status of installed MPCs. As shown in the sample
output, the value Online in the column labeled State indicates that the MPC in slot 1 is functioning
normally:
Verify if the MPC is offline:
user@host> show chassis fpc
node0:
--------------------------------------------------------------------------
Temp CPU Utilization (%) Memory Utilization (%)
38