Table 53: Chassis Component Alarm Conditions on SRX5400, SRX5600, and SRX5800 Services
Gateways (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
RedOpen a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
Abnormal exit in the current
flow sessions of an SPU.
Service
Processing Card
(SPC)
RedCheck the status of all fan
trays.
CPU Digital Thermal Sensor
(DTS) of the SPC reaches
high or over temperature
threshold.
RedCheck the status of all fan
trays.
FPC airflow temperature
sensors in SRX5K-SPC3
reach high or over or
crosses fire temperature
threshold.
YellowIf the alarm is present
consistently, then it
indicates a hardware issue.
Open a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
FPC airflow temperature
sensors in SRX5K-SPC3
read/access failure.
RedOpen a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
SRX5K-SPC3 checks for
missing devices during boot
and reports.
Red
340