Table 53: Chassis Component Alarm Conditions on SRX5400, SRX5600, and SRX5800 Services
Gateways (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
RedInstall missing fan tray.A fan tray has been
removed from the chassis.
Fan trays
RedReplace fan tray.Fan tray not working or
failed.
RedReplace fan tray.One fan in the chassis is not
spinning or is spinning
below required speed.
YellowUpgrade to a high-capacity
fan tray.
A higher-cooling capacity
fan tray is required when an
MPC or high-density SPCs
are installed on the chassis.
RedReseat the Fan Tray. If
problem still continues
open a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
Fan tray under voltage.
RedCheck and insert the
appropriate fan tray.
Wrong fan tray installed.
RedInsert the appropriate fan
trays.
In SRX5800 Services
Gateway, mix of fan trays.
RedCheck and insert the
appropriate fan tray.
In SRX5800 Services
Gateway, wrong fan tray
installed on the top.
345