FlexLine plus, Technical Data
175
Power
Internal battery
Environmental
specifications
Temperature
Protection against water, dust and sand
Humidity
Arctic model
Electronic Guide
Light EGL
Available for instruments.
Automatic
corrections
The following automatic corrections are made:
External supply voltage:
(via serial interface)
Nominal voltage 12.8 V DC, Range 11.5 V-14 V
Type Battery Voltage Capacity
Operating time, typically
*
GEB211 Li-Ion 7.4 V 2.2 Ah ~ 10 h
GEB212 Li-Ion 7.4 V 2.6 Ah ~ 12 h
GEB221 Li-Ion 7.4 V 4.4 Ah ~ 20 h
GEB222 Li-Ion 7.4 V 6.0 Ah ~ 30 h
* Based on a single measurement every 30 s at 25°C. Operating time may be shorter
if battery is not new.
Type Operating temperature Storage temperature
[°C] [°F] [°C] [°F]
All instruments -20 to +50 -4 to +122 -40 to +70 -40 to +158
Battery -20 to +50 -4 to +122 -40 to +70 -40 to +158
USB memory stick -40 to +85 -40 to +185 -50 to +95 -58 to +203
Type Protection
All instruments IP55 (IEC 60529)
Type Protection
All instruments Max 95% non condensing.
The effects of condensation are to be effectively counteracted by
periodically drying out the instrument.
Operating range: -35°C to +50°C (-31°F to +122°F)
To minimise unavoidable slowdown of display performance for the
Arctic option, switch display heating on and connect the external
battery. Allow for a short warm-up time.
Working range: 5 m to 150 m (15 ft to 500 ft)
Position accuracy: 5 cm at 100 m (1.97" at 330 ft)
• Line of sight error • Vertical index error
• Tilting axis error • Refraction
• Earth curvature • Compensator index error
• Standing axis tilt • Circle eccentricity