FlexLine plus, Settings
50
User prism constant
Leica Const.
Abs. Const.
= -30.0 mm
= +4.4 mm (34.4 + -30 = 4.4)
= -30.0 mm
Meas. Mode Precise+ Fine measuring mode for highest precision measure-
ments with prisms (1.5 mm + 2 ppm).
Precise&Fast Quick measuring mode with prisms, with higher meas-
uring speed and high accuracy (2 mm + 2 ppm).
Precise For distance measurements without prisms
(2 mm + 2 ppm; >500 m: 4 mm + 2 ppm).
Average Repeats measurements in standard measuring mode.
Define the number of repetitions in No. of Meas.. The
average distance and the standard deviation for the
averaged distance are calculated.
During the measurement, a status bar, the calculated
slope distance and the standard deviation are displayed.
Use Back to return to the previous screen without
storing the data. Use Re-meas to omit all previous
measurements and to restart. Use Cont to cancel the
measurement process and to calculate the average from
the available measurements.
Tracking For continuous distance measurements with prisms
(3 mm + 2 ppm) or without prisms (5 mm + 3 ppm).
Prism
(>4.0km)
For long range distance measurements with prisms
(5 mm + 2 ppm). Available for instruments.
No. of Meas. The number of repeated measurements.
Limit value: 2 to 99
Leica Const. This field displays the Leica prism constant for the selected Prism
Type.
Where Prism Type is User 1 or User 2 this field becomes editable to
set a user defined constant. Input can only be made in mm.
Limit value: -999.9 mm to +999.9 mm.
Abs. Const. This field displays the absolute prism constant for the selected Prism
Type.
Where Prism Type is User 1 or User 2 this field becomes editable to
set a user defined constant. Input can only be made in mm.
Limit value: -999.9 mm to +999.9 mm.
Laser-Point Off Visible laser beam is deactivated.
On Visible laser beam for visualising the target point is acti-
vated.
Guide Light Available for instruments.
Off Guide Light is deactivated.
On Guide Light is activated. The person at the prism can be
guided by the flashing lights directly to the line of sight.
The light points are visible up to a distance of 150
meters. This is useful when staking out points.
Working range: 5 m to 150 m (15 ft to 500 ft).
Positioning accuracy: 5 cm at 100 m (1.97" at 330 ft).
Field Description