Page 248
REPAIR INSTRUCTIONS, PART 1
268
Figure 268 — Checking Valve Spring Pressure
Injection Nozzle Holder Insert
Replacement
[213 GB]
The injection nozzle holder insert is machined to
provide a press-fit in the cylinder head.
REMOVAL PROCEDURE
1. To remove the injection nozzle holder insert,
tap the ID with a 24 mm -3 tap to a depth of
approximately 1-1/2 inches (38 mm).
2. Install the nozzle sleeve (insert) puller
J 42678 to the slide hammer J 2619-01, or
equivalent, as shown in Figure 269.
3. Thread the puller into the end of the nozzle
holder insert and use the slide hammer to
remove the insert.
269
Figure 269 — Removing Injection Nozzle Holder Insert
1. Spring Tester J 22738-02 2. Valve Spring
1. Slide Hammer J 2619-01 2. Sleeve Puller J 42678
5-111.bk Page 248 Monday, July 10, 2006 2:26 PM