8 Description of Function Codes NICE3000
new
User Manual
- 220 -
8
Bit Function Description Default
Bit5 Reserved - 0
Bit6 Reserved - 0
Bit7 Reserved - 0
Bit8
Emergency running
time protection
If the elevator does not arrive at the required oor after 50s emergency
evacuation running time, Err33 is reported. In this case, the function of
switching over shorting stator braking mode to controller drive based on the
time setting cannot be implemented.
0
Bit9 Reserved - 0
Bit10
Emergency buzzer
output
The buzzer tweets at intervals in the emergency evacuation running state. 0
Bit11 Reserved - 0
Bit12
Shorting stator
braking mode
switched over to
controller drive
It enables the function of switching over shorting stator braking mode to
controller drive.
0
Bit13
Mode of shorting
stator braking mode
switched over to
controller drive
0
Time setting
If the time of the shorting stator braking mode exceeds 50s, the
controller starts to drive the elevator.
0
1
Speed setting
If the speed is still smaller than the value of F6-48 after 10s in the
shorting stator braking mode, the controller starts to drive the elevator.
Bit14
Emergency
evacuation exit mode
0
The system exits emergency evacuation when receiving the door open
limit signal from the elevator that arrives at the target oor.
0
1
The system exits emergency evacuation when receiving the door close
limit signal from the elevator that arrives at the target oor.
Bit15
Shorting stator
braking function
When this function is enabled (Bit15 = 1), the setting of related function
codes becomes effective.
0
For details on the emergency evacuation function, see section 6.2.2.
8.8.8 VIP Function
Function Code Parameter Name Setting Range Default Unit Property
F6-12
VIP oor 0 to F6-00 0
-
★
F6-46
VIP function selection 0–65535 0
-
★
F6-12 is used to set the VIP oor.
F6-46 is used to select the elevator VIP function. Each bit of the function code denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-46 are described in the following table.
Bit Function Description Default
Bit0
VIP enabled by hall call at
VIP oor
After this function is enabled, the system enters VIP running. 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Monarch nice3000 and is the answer not in the manual?

Monarch nice3000 Specifications

General IconGeneral
BrandMonarch
Modelnice3000
CategoryController
LanguageEnglish

Related product manuals