NICE3000
new
User Manual 10 Technical Data
- 287 -
Item Specication
I/O feature
Digital input (DI)
24 x DI
Input specication: 24 V, 5 mA
3 heavy-current detection input terminals of safety circuit and door lock
circuit
Input specication: 95−125 V
Analog input (AI) AI (voltage range: –10 V to +10 V)
Communication port
2 CANbus communication ports
1 Modbus communication port
Output terminal block
6 relay outputs
The terminals can be allocated with different functions.
Encoder interface Supporting different encoders by using an optional PG card
Operation
and display
Keypad 3-digit LED display, implementing certain commissioning functions
LED operation panel
5-digit LED display, querying/modifying most parameters and monitoring
the system state
Status monitor
Connecting the control system and the host computer, convenient for
querying/motoring the system state.
Environment
Altitude Below 1000 m (de-rated 1% for each 100 m higher)
Ambient temperature
–10°C to 40°C (de-rated if the ambient temperature is above 40°C,
maximum temperature: 50°C)
Humidity Maximum relative humidity 95%, non-condensing
Vibration Maximum vibration: 5.9 m/s
2
(10–55 Hz, 0.35 mm)
Storage temperature –20°C to 60°C
IP level IP20
Pollution degree PD2
Power distribution
system
TN, TT
10.2 Derating
As the altitude increases, the output power of the NICE3000
new
must be derated according to the following
gure.