NICE3000
new
User Manual 10 Technical Data
- 287 -
10
Item Specication
I/O feature
Digital input (DI)
24 x DI
Input specication: 24 V, 5 mA
3 heavy-current detection input terminals of safety circuit and door lock
circuit
Input specication: 95−125 V
Analog input (AI) AI (voltage range: –10 V to +10 V)
Communication port
2 CANbus communication ports
1 Modbus communication port
Output terminal block
6 relay outputs
The terminals can be allocated with different functions.
Encoder interface Supporting different encoders by using an optional PG card
Operation
and display
Keypad 3-digit LED display, implementing certain commissioning functions
LED operation panel
5-digit LED display, querying/modifying most parameters and monitoring
the system state
Status monitor
Connecting the control system and the host computer, convenient for
querying/motoring the system state.
Environment
Altitude Below 1000 m (de-rated 1% for each 100 m higher)
Ambient temperature
–10°C to 40°C (de-rated if the ambient temperature is above 40°C,
maximum temperature: 50°C)
Humidity Maximum relative humidity 95%, non-condensing
Vibration Maximum vibration: 5.9 m/s
2
(10–55 Hz, 0.35 mm)
Storage temperature –20°C to 60°C
IP level IP20
Pollution degree PD2
Power distribution
system
TN, TT
10.2 Derating
As the altitude increases, the output power of the NICE3000
new
must be derated according to the following
gure.