8 Description of Function Codes NICE3000
new
User Manual
- 244 -
8.13.10 Keypad Display Selection
Function Code Parameter Name Setting Range Default Unit Property
FA-00
Keypad display selection 0–3 3 -
☆
The NICE3000
new
system has three buttons and three 7-segment LEDs on the MCB. You can change the
display content through the setting of this parameter.
●
0: Reversed display of physical oor
●
1: Positive display of physical oor
●
2: Reversed display of hall call oor
●
3: Positive display of hall call oor
8.14 Door Function Parameters
8.14.1 Door Machine and Opposite Door Function
Function Code Parameter Name Setting Range Default Unit Property
Fb-00
Number of door machine(s) 1–2 1 -
★
FC-04
Opposite door control selection 0–3 0 -
★
●
Fb-00 is used to set the number of door machine(s).
Set it to 1 if there is only one door, and 2 if there are double doors.
●
FC-04 is used to set opposite door-related control function.
The values are as follows:
● 0: Simultaneous control
● 1: Hall call independent, car call simultaneous
● 2: Hall call independent, car call manual control
● 3: Hall call independent, car call independent
For details on the use of the opposite door, see section 6.2.4.
8.14.2 Door Open/Close Time and Arrive Gong Delay
Function Code Parameter Name Setting Range Default Unit Property
Fb-06
Door open protection time 5–99 10 s
☆
Fb-07
Arrival gong output delay 0–1000 0 ms
☆
Fb-08
Door close protection time 5–99 15 s
☆
●
FB-06 is used to set the door open protection time.
After outputting the door open command, if the system does not receive the door open limit signal
after the time set in this parameter, the system re-opens the door. When the door open/close