8 Description of Function Codes NICE3000
new
User Manual
- 226 -
8
in F8-06 and F8-07. You can also manually input the data according to the actual situation.
F8-01 is used to set the pre-torque compensation mode at startup of the elevator.
The values are as follows:
0: Pre-torque invalid
Load cell auto-tuning is allowed.
1: Load cell pre-torque compensation
With a load cell, the system implements the pre-torque compensation function.
2: Automatic pre-torque compensation
The system automatically adjusts the compensated torque at startup without a load cell.
If F8-01 is set to 1, the system outputs the torque matching the load in advance to ensure the
riding comfort at startup. The output torque is limited by F2-08 (Torque upper limit). When the
load torque is greater than the set torque upper limit, the output torque of the system is the torque
upper limit.
F8-02 is used to set the pre-torque offset. It is actually the balance coefcient of the elevator,
indicating the percentage of the car load to the rated load when the counterweight and the car
weight are balanced.
F8-05 is readable and reects the load condition in the car. The value is sampled by the
NICE3000
new
by using a load cell to judge overload or full-load, or calculate the torque current for
load cell pre-torque compensation.
F8-06 and F8-07 respectively records the car no-load and full-load conditions in the car. They are
AD sampling values.
8.11.2 Pre-torque Gain
Function Code Parameter Name Setting Range Default Unit Property
F8-03
Drive gain 0.00–2.00 0.60
-
F8-04
Brake gain 0.00–2.00 0.60
-
These two parameters are used to set the pre-torque gain when the elevator runs on the drive side or the
brake side.
For details, see section 6.1.6.
8.11.3 Anti-nuisance Function
Function Code Parameter Name Setting Range Default Unit Property
F8-08
Anti-nuisance function 0, 1, 2, 4 0 -
It is the criteria for judging whether nuisance exists.
The values are as follows:
0: Anti-nuisance function disabled