User Manual 8 Description of Function Codes
- 217 -
The elevator responds to down hall calls but does not respond to up hall calls.
●
2: Up collective selective
The elevator responds to hall up calls but does not respond to hall down calls.
Function Code Parameter Name Setting Range Default Unit Property
FE-32
Elevator function selection 1
Bit6: Down collective
selective peak service
0 -
☆
F6-14
Start time of down collective selective 1 00.00–23.59 00.00 HH.MM
☆
F6-15
End time of down collective selective 1 00.00–23.59 00.00 HH.MM
☆
F6-16
Start time of down collective selective 2 00.00–23.59 00.00 HH.MM
☆
F6-17
End time of down collective selective 2 00.00–23.59 00.00 HH.MM
☆
To enable the down collective selective peak service, set FE-32 Bit6 to 1.
F6-14 to F6-17 dene the time periods of down collective selective 1 and down collective selective 2,
during which, the elevator responds to only downward hall calls.
8.8.4 Setting for Returning to Parking Floor at Idle
Function Code Parameter Name Setting Range Default Unit Property
F6-02
Parking oor F6-01 to F6-00 1
-
★
F9-00
Idle time before returning to base oor 0–240 10 min
☆
When the idle time of the elevator exceeds the value set in F9-00, the elevator returns to the parking oor
set in F6-02 automatically.
8.8.5 Parallel/Group Control Function
Function Code Parameter Name Setting Range Default Unit Property
F6-07
Number of elevators in
parallel/group mode
1–8 1 -
★
F6-08
Elevator No. 1–8 1 -
★
F6-09
Elevator program control
Bit0: Dispersed waiting
Bit3: Parallel/Group control
implemented at CAN2
Bit4: Group control in
compatibility with NICE3000
0 -
★
F6-07 and F6-08 are used to set the number of elevators and elevator No. in parallel/group mode.
Bit0 to Bit4 of F6-09 are used to set different parallel/group control modes. For details, see section 6.2.3.
Function Code Parameter Name Setting Range Default Unit Property
FE-32
Elevator function selection 1
Bit7: Parallel/Group control
peak service
0 -
☆
F6-26
Peak 1 start time 00.00–23.59 00.00
HH.MM
☆
F6-27
Peak 1 end time 00.00–23.59 00.00
HH.MM
☆