8 Description of Function Codes NICE3000
new
User Manual
- 218 -
Function Code Parameter Name Setting Range Default Unit Property
F6-28
Peak 1 oor F6-01 to F6-00 1
-
★
F6-29
Peak 2 start time 00.00–23.59 00.00
HH.MM
☆
F6-30
Peak 2 end time 00.00–23.59 00.00
HH.MM
☆
F6-31
Peak 2 oor F6-01 to F6-00 1
-
★
To enable the parallel/group control peak service, set FE-32 Bit7 to 1.
F6-26 to F6-28 are used to set peak service time period 1 and corresponding service oors.
F6-29 to F6-31 are used to set peak service time period 2 and corresponding service oors.
During a peak time period, if there are more than three car calls from the peak oor, the elevator enters
the peak service state. At the moment, the car calls from the peak oor are valid all the time. The elevator
returns to this oor if it is idle.
8.8.6 Attendant Function
Function Code Parameter Name Setting Range Default Unit Property
F5-00
Attendant/Automatic switchover time 3–200 3 s
★
F6-43
Attendant function selection 0–65535 0
-
★
If there is a hall call at non-current oor in attendant state, the system automatically switches over to the
automatic (normal) state after the time set in this parameter. After this running is completed, the system
automatically restores to the attendant state (F6-43 Bit2 must be set to 1).
When the value of this parameter is smaller than 5, this function is disabled, and the system is in the
normal attendant state.
F6-43 is used to select the attendant-related elevator functions. Each bit of the function code denes a
function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-43 are described in the following table.
Bit Function Description Default
Bit0
Calls cancelled after
entering attendant state
All car calls and hall calls are cancelled after the system enters
the attendant state for the rst time.
0
Bit1 Not responding to hall calls
The car blinks inside, prompting there is a hall call, but the system
does not respond.
0
Bit2
Attendant/Automatic state
switchover
If this function is enabled, the setting of F5-00 is valid. 0
Bit3 Door close at jogging
The elevator door closes after the attendant presses the door
close button manually.
0
Bit4 Automatic door close
It is the same as the normal state. After the door open holding
time is reached, the door closes automatically.
0
Bit5
Buzzer tweeting at intervals
in attendant state
When the hall call oor and the car call oor are different, the
buzzer tweets 2.5s at intervals.
0