8 Description of Function Codes NICE3000
new
User Manual
- 216 -
Function Code Parameter Name Setting Range Default Unit Property
Fb-18
Door machine 1 service oors 3 (oors 33–40) 0–65535 65535 -
☆
Fb-04
Door machine 2 service oors 1 (oors 1–16) 0–65535 65535 -
☆
Fb-05
Door machine 2 service oors 2 (oors 17–32) 0–65535 65535 -
☆
Fb-19
Door machine 2 service oors 3 (oors 33–40) 0–65535 65535 -
☆
These parameters are used to set the service oors of door machine 1 and door machine 2.
The setting method is the same as that for F6-05.
Function Code Parameter Name Setting Range Default Unit Property
FE-32
Elevator function selection 1
Bit8: Time-based
oor service
0 -
☆
F6-18
Start time of time-based oor service 1 00.00–23.59 00.00 HH.MM
☆
F6-19
End time of time-based oor service 1 00.00–23.59 00.00 HH.MM
☆
F6-20
Service oor 1 of time-based oor service 1 0–65535 65535 -
☆
F6-21
Service oor 2 of time-based oor service 1 0–65535 65535 -
☆
F6-36
Service oor 3 of time-based oor service 1 0–65535 65535 -
☆
F6-22
Start time of time-based oor service 2 00.00–23.59 00.00 HH.MM
☆
F6-23
End time of time-based oor service 2 00.00–23.59 00.00 HH.MM
☆
F6-24
Service oor 1 of time-based oor service 2 0–65535 65535 -
☆
F6-25
Service oor 2 of time-based oor service 2 0–65535 65535 -
☆
F6-37
Service oor 3 of time-based oor service 2 0–65535 65535 -
☆
To enable the time-based oor service, set FE-32 Bit8 to 1. Then, you can set the time range and service
oors of two groups of time-based oor services.
Service oor 1 corresponds to oors 1–16, service oor 2 corresponds to oors 17–32, and service oor 3
corresponds to oors 33–30.
In the time period of time-based oor service 1 (set by F6-18 and F6-19), the elevator responds to the
service oors set by F6-20, F6-21 and F6-36 but ignores the service oors set by F6-05, F6-06 and F5-35.
The setting of time-based service oors is the same as that of service oors in F6-05.
8.8.3 Collective Selective Function
Function Code Parameter Name Setting Range Default Unit Property
FE-00
Collective selective mode 0–2 0 -
★
It is used to set the collective selective mode of the system.
The values are as follows:
●
0: Full collective selective
The elevator responds to both up and down hall calls.
●
1: Down collective selective