8 Description of Function Codes NICE3000
new
User Manual
- 256 -
Figure 8-33 Viewing bits cyclically
Decimal
display
Bit15
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
Bit8
Bit9
Bit10
Bit11
Bit12
Bit13
Bit14
8.21.2 Function Codes in Bit
The function codes that can be viewed and set in bit are listed in the following table.
Function Code Description
F5-25 See the description in section 8.6.5.
F5-33
See the following part.
F6-09
F6-11
F6-40
F6-41
F6-42
F6-43 See the description in section 8.8.6.
F6-44 See the description in section 8.9.1.
F6-45 See the description in section 8.8.7.
FC-00
See the following part.
FC-01
FE-32
FE-33
â—†
F5-33 Terminal Program Control
Function Code Parameter Name Setting Range Default Unit Property
F5-33
Terminal program control 0–65535 0 -
★
F5-33 is used to select the elevator functions. Each bit of the function code denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F5-33 are described in the following table.
Bit Function Description Default
Bit3
Elevator re emergency
requirement for Hong Kong
If it is enabled, the re emergency functions in F6-44
applied to Hong Kong become enabled automatically.
0
Bit4 Arrival gong disabled at night The arrival gong is disabled from 22:00 p.m. to 7:00 a.m. 0
Bit6
Door lock disconnected at
inspection switched over to normal
running
The door lock is additionally disconnected once when the
inspection state is switched over to the normal running
state.
0