NICE3000
new
User Manual 8 Description of Function Codes
- 257 -
Bit Function Description Default
Bit7
Fault code not displayed on the
keypad
The keypad does not blink to display the fault code. 0
Bit8
Door open command cancelled
immediately at door open limit
The system immediately cancels the door open command
after receiving the door open limit.
0
Bit9
Car stop and zero-speed torque
holding at abnormal brake
feedback
When the brake feedback is abnormal, the elevator arrives
at the door-zone position and stops. The door keeps
closed, and the system holds torque output as long as
possible. After the system is overloaded, there is no torque
output, and the elevator may fall in this case. Be cautious
of using this function.
0
â—†
F6-09 Elevator Program Control
Function Code Parameter Name Setting Range Default Unit Property
F6-09
Elevator program control 0–65535 0 -
★
F6-09 is used to select the elevator functions. Each bit of the function code denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-09 are described in the following table.
Bit Function Description Default
Bit0 Dispersed waiting
In single elevator or parallel/group mode, if this function is enabled, an
idle elevator will not return to the base oor.
In group mode, this function is used together with the group control
board to implement dispersed waiting.
0
Bit3
Parallel/Group control
implemented at CAN2
This function is enabled when the parallel/group mode is implemented
at CAN2 on the MCB.
0
Bit4
Group control in
compatibility with
NICE3000
This function is used when the NICE3000 is involved in the group
control system. The setting of this bit must be the same as that for all
the other elevators in the group.
0
Bit6
Clear oor number
and display direction in
advance
The displayed oor number is cleared before the elevator reaches the
target oor.
If the elevator needs to change the direction, the changed direction is
displayed in advance.
0
Bit8 Single hall call button It is applied to applications where there is only one hall call button. 0
Bit9
Not detecting analog
wire breaking
The system does not detect analog wire breaking during normal
running.
0
Bit10
Err30 judgment at re-
leveling cancellation
It indicates Err30 judgment when re-leveling is cancelled. 0
Bit14
Time interval detection
of safety circuit 2 and
door lock circuit 2
If the states of safety circuits 1 and 2 or the states of door lock circuits
1 and 2 are inconsistent, the system will prohibit running. After the
states restore normal, the system is powered on again and starts
running.
0