8 Description of Function Codes NICE3000
new
User Manual
- 258 -
8
â—†
F6-11 Elevator Function Selection
Function Code Parameter Name Setting Range Default Unit Property
F6-11 Elevator function selection 0–65535 8448 -
★
F6-11 is used to select the elevator functions. Each bit of the function code denes a function, as described
in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-11 are described in the following table.
Bit Function Description Default
Bit1
Disabling returning to
base oor for verication
The function of returning to base oor for verication due to large
deviation of the car position is disabled.
0
Bit2
Cancelling auto
sequential arrange of
hall call oor addresses
to be displayed
If the display of a oor in group FE is set to 1, the following oors to be
displayed are automatically arranged in the ascending order.
0
Bit5
Current detection
valid at startup for
synchronous motor
The controller performs output current detection when the synchronous
motor is started up. If the current is abnormal, the output will be locked
and the running will be forbidden.
0
Bit6
Reversing MCB lamp
output
After this function is enabled, the MCB lamp output logic is reversed. 0
Bit7
Door open valid at
non-door zone in the
inspection state
In the inspection state, you can open/close the door by pressing the
door open/close button at the non-door zone.
0
Bit8
Door open and close
once after inspection
turned to normal
The elevator door opens and closes once after the system turns from
rst-time inspection to normal running.
1
Bit10
Buzzer not tweet upon
re-leveling
The buzzer inside the car does not tweet upon re-leveling. 0
Bit11
Super short oor
function
The controller cannot perform shaft-tuning if the oor height is less
than 500 mm. After this function is enabled, shaft-tuning can be
performed normally.
0
Bit12 Fault auto reset The controller automatically resets the faults once every hour. 0
Bit13 Err53 fault auto reset
When Err53 is reported, if the conditions of door open limit valid
and door lock release are satised, the controller resets Err53
automatically. A maximum of three times of auto reset is allowed.
1
Bit14
Up slow-down not reset
for super short oor
If this function is enabled, the up slow-down 1 signal does not reset
oor display. The down slow-down 1 signal still resets oor display.
This is valid only when the customized super short oor function is
enabled.
0
Bit15
Down slow-down not
reset for super short
oor
If this function is enabled, the down slow-down 1 signal does not reset
oor display. The up slow-down 1 signal still resets oor display. This
is valid only when the customized super short oor function is enabled.
0