EasyManua.ls Logo

Monarch nice3000 - Supplementary Precautions

Monarch nice3000
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NICE3000
new
User Manual
1 Safety Instructions
- 17 -
1
7. During Maintenance
DANGER
Repair and maintenance operations on the controller must be performed only by qualied technicians.
Never repair or main the controller while the power is on. Follow the repair and maintenance instructions in
this user manual.
Repair or maintain the controller when its voltage is lower than 36 VAC, about 10 minutes after the
controller is powered off. Otherwise, the residual voltage in the capacitor may result in personal injury.
Disconnect the controller from all power supply before starting any repair or maintenance operations.
All the pluggable components must be plugged or removed only after power-off.
Perform parameter setting and check after the controller is replaced.
WARNING
The rotating motor feeds power back to the controller system. The controller is still charged even if the motor
stops and the power is cut off. Therefore, ensure that the motor is completely disconnected from the controller
before starting any maintenance on the controller.
Controller Label Warnings
The controller labels the warning information on the front or terminal cover. Obey the warning information
during the use.
Read the manual and follow the safety instructions
before use
Wait 10 mins power down before removing cover
Risk of electric shock
WARNING
Restrictions
The controller is not designed or manufactured for use in devices or systems that may directly
affect or threaten human lives or health.
Customers who intend to arrange the controller for special use such as device or system relating
to health care, space aviation, nuclear energy, electric power, or in underwater applications must
contact our agent or sales representatives.
The controller has been manufactured under strict quality control. However, if this product is to
be installed in any location where the fault of this product may result in a severe accident or loss,
install safety devices.
1.2 Supplementary Precautions
1. Requirements of a residual current device (RCD)
The controller generates high leakage current during running, which ows through the protective
earthing (PE) conductor. Thus install a type-B RCD at primary side of the power supply. When