10 Technical Data NICE3000
new
User Manual
- 286 -
Chapter 10 Technical Data
10.1 General Technical Specications
Table 10-1 NICE3000
new
technical specications
Item Specication
Basic
specications
Maximum frequency 99 Hz
Carrier frequency 2–16 kHz, adjusted automatically based on the load features
Motor control mode
● Sensorless vector control (SVC)
● Closed-loop vector control (CLVC)
● Voltage/Frequency (V/F) control
Startup torque
● 0.5 Hz: 180% (SVC)
● 0 Hz: 200% (CLVC)
Speed adjustment range
● 1:100 (SVC)
● 1:1000 (CLVC)
● 1:50 (V/F)
Speed stability accuracy
● ±0.5% (SVC)
● ±0.05% (CLVC)
Torque control accuracy ±5% (CLVC)
Overload 60s for 150% of the rated current, 1s for 200% of the rated current
Motor auto-tuning With-load auto-tuning; no-load auto-tuning
Distance control
Direct travel ride mode in which the leveling position can be adjusted
exibly
Acceleration/
Deceleration curve
N curves generated automatically
Slow-down
New reliable slow-down function, automatically identifying the position of
the slow-down shelf
Shaft auto-tuning 32-bit data, recording the position in the shaft accurately
Leveling adjustment Flexible and easy leveling adjustment function
Startup torque
compensation
● Load cell startup pre-torque compensation
● No-load-cell startup pre-torque self-adaption
Real-time clock
Real-time clock for time-based oor service, peak service and automatic
password
Test function Easy to implement multiple elevators commissioning functions.
Fault protection Solutions to different levels of elevator faults
Intelligent management Remote monitoring, user management, and group control adjustment
Security check of
peripheral devices after
power-on
Security check of peripheral devices, such as grounding and short
circuit, after power-on
Status monitor
Monitoring the state of feedback signals to ensure that the elevator
works properly