4 Peripheral Devices and Options NICE3000
new
User Manual
- 68 -
4
Fuse, Contactor, Circuit Breaker, Reactors and Filters
For model selection of the EMC devices such as fuse, contactor, circuit breaker, reactors, and lters, refer
to Chapter 12.
Braking Components
The braking components are common optional parts provided by Inovance. For details, see section 4.3.
Adaptable Motor
Table 4-3 Adaptable motor selection
Controller Model
Power Capacity
(kVA)
Input Current
(A)
Output Current
(A)
Adaptable Motor (kW)
Single-phase 220 V, range:220–240 V
NICE-L-C-2002 2.0 9.2 5.2 1.1
NICE-L-C-2003 2.9 13.3 7.5 1.5
220-NICE-L-C-4007 3.9 17.9 10.3 2.2
220-NICE-L-C-4011 5.9 25.3 15.5 3.7
220-NICE-L-C-4015 7.3 31.3 19 4.0
220-NICE-L-C-4018 8.6 34.6 22.5 5.5
220-NICE-L-C-4022 10.6 42.6 27.7 11
220-NICE-L-C-4030 13.1 52.6 34.6 15
Three-phase 220 V, range: 220–240 V
NICE-L-C-2002 4.0 11.0 9.6 2.2
NICE-L-C-2003 5.9 17.0 14.0 3.7
220-NICE-L-C-4007 7.0 20.5 18.0 4.0
220-NICE-L-C-4011 10.0 29.0 27.0 5.5
220-NICE-L-C-4015 12.6 36.0 33.0 7.5
220-NICE-L-C-4018 15.0 41.0 39.0 11.0
220-NICE-L-C-4022 18.3 49.0 48.0 15.0
220-NICE-L-C-4030 23.0 62.0 60.0 18.5
Three-phase 380 V, range: 380–440 V
NICE-L-C-4002 4.0 6.5 5.1 2.2
NICE-L-C-4003 5.9 10.5 9.0 3.7
NICE-L-C-4005 8.9 14.8 13.0 5.5
NICE-L-C-4007 11.0 20.5 18.0 7.5
NICE-L-C-4011 17.0 29.0 27.0 11.0
NICE-L-C-4015 21.0 36.0 33.0 15.0
NICE-L-C-4018 24.0 41.0 39.0 18.5
NICE-L-C-4022 30.0 49.5 48.0 22.0
NICE-L-C-4030 40.0 62.0 60.0 30.0
NICE-L-C-4037 57.0 77.0 75.0 37.0
NICE-L-C-4045 69.0 93.0 91.0 45.0