Electra Elite Issue 6
Features and Specifications Manual A - 53
1. Receive an incoming CO/PBX call.
2. The Automatic Answer with Delay Message answers the call and
sends a greeting.
3. The outside party hears ringback tone or MOH (System
Programmed).
4. After the time expires, a second message is played.
5. The outside party hears ringback tone or MOH until the call is
answered.
SERVICE
CONDITIONS
Data Assignment:
A maximum of two VRS(4)-U10 ETUs, four channels per ETU, can
be used for Automated Attendant.
Each channel has 240 recording seconds that can be subdivided into
2, 4, 8, or 16 equal recording times.
A maximum of eight Automated Attendants can be assigned.
Use Memory Block 1-4-11 (Automated Attendant Message Day/Night
Mode Selection) to assign the Day/Night/Weekend mode greeting
messages to each Automated Attendant position.
Use Memory Block 1-4-13 (Automated Attendant Answer Delay Time
Assignment) to set the answering time (default: 4 seconds) between
when the incoming CO/PBX call rings and when it is answered. This
time affects the Day/Night/Weekend mode settings per Automated
Attendant.
Use Memory Block 1-4-16 (Automated Attendant Message Repeat
Selection) to assign the number of times a greeting message is
repeated (default: 1).
Use Memory Block 1-8-07 [Class of Service (Attendant) Feature
Selection 1] Page 1 LK8 to Allow (default: LED On) or Deny (LED
Off) Attendant Positions to set/reset the Automated Attendant per
trunk.
Use Memory Block 1-8-08 [Class of Service (Station) Feature
Selection 2] Page 2 LK6 to Allow (default: LED On) or Deny (LED
Off) the station to record, verify, or erase an Automated Attendant
message.
To answer by Two Levels: