Program 15 : Extension, Basic Setup
15-22 : Mobile Extension Setup
Level
IN
Description
Use Program 15-22 : Mobile Extension Setup to set the system information for the Mobile Extension
feature.
Input Data
Extension Number Up to four digits (SL1000)
Up to eight digits (SL1100)
Item No. Item Input Data Default
01 Mobile Extension Target Setup
Set which Speed Dial bin is used to call when
the Mobile extension is called.
0 ~ 999 (0 = No setting/1 ~ 999 = target
of mobile extension)
0
02 Connect Confirmation
Select when a confirmation (dial
*
)isrequired
to allow the call to cut over to the called mobile
number.
0 = Always
1 = On Analog Line
2 = Never
0
03 Trunk Access Code
Select if the Normal (0) or Individual (1) Trunk
access is used when making the call to the mo-
bile number.
0 = Use normal trunk access code (Pro-
gram 11-09-01)
1 = Use individual trunk access code
(Program 11-09-02)
0
04 Call Back 0 = Disable
1 = Enable
0
Conditions
None
Feature Cross Reference
None
ISSUE 1.0 SL1000/SL1100
Program
15
Programming Manual 2-149