Program 84 : Hardware Setup for VoIPDB
84-02 : H.225 and H.245 Information Basic Setup
Level
IN
Description
Use Program 84-02 : H.225 and H.245 Information Basic Setup to define the basic setup informa-
tion of H.225 and H.245.
Input Data
Item No. Item Input Data Default
01 H.225 Alerting Time 0 ~ 255 seconds 180
02 H.225 Setup Acknowledge Timer 0 ~ 255 seconds 9
03 H.225 Setup Timer 0 ~ 255 seconds 4
04 H.225 Info Ack Timer 0 ~ 255 seconds 9
05 H.225 Call Proceeding Timer 0 ~ 255 seconds 10
07 H.245 Master Slave Determination Timer 0 ~ 255 seconds 5
08
H.245 Master Slave Determination Retry
Count
0 ~ 255 seconds 3
09 H.245 Capability Exchange Timer 0 ~ 255 seconds 5
10
H.245 Logical Channel Establishment
Timer
0 ~ 255 seconds 50
11 H.245 Mode Request Procedures Timer 0 ~ 255 seconds 50
12 H.245 Close Logical Channel Timer 0 ~ 255 seconds 50
13 H.245 Round Trip Delay Timer 0 ~ 255 seconds 50
14 H.245 Maintenance Loop 0 ~ 255 seconds 50
15 RAS GRQ Timer 0 ~ 255 seconds 5
16 GRQ Retry Count 0 ~ 255 2
17 RAS RRQ Timer 0 ~ 255 seconds 5
18 RRQ Retry Count 0 ~ 255 3
19 RAS URQ Timer 0 ~ 255 seconds 3
20 URQ Retry Count 0 ~ 255 1
21 RAS ARQ Timer 0 ~ 255 seconds 5
22 ARQ Retry Count 0 ~ 255 2
23 RAS BRQ Timer 0 ~ 255 seconds 5
24 BRQ Retry Count 0 ~ 255 2
25 RAS IRR Timer 0 ~ 255 seconds 5
26 IRR Retry Count 0 ~ 255 2
27 RAS DRQ Timer 0 ~ 255 seconds 8
28 DRQ Retry Count 0 ~ 255 2
29 RAS LRQ Timer 0 ~ 255 seconds 5
30 LRQ Retry Count 0 ~ 255 2
31 RAS RAI Timer 0 ~ 255 seconds 3
ISSUE 1.0SL1000/SL1100