Program 14 : Trunk, Basic Setup
14-02 : Analog Trunk Data Setup
Level
IN
Description
Use Program 14-02 : Analog Trunk Data Setup to set the basic options for each analog trunk port.
Refer to the table below for a description of each option, its range and default setting.
Input Data
Trunk Port Number
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Item
No.
Item Input Data Default
Related Pro-
gram
Note
01 Signaling Type (DP/DTMF)
This option sets the signaling
type for the trunk.
0 = Dial Pulse (10 PPS)
2 = DTMF
2
02 Ring Detect Type
This option sets Extended Ring
Detect or Immediate Ring De-
tect for the trunk. For T1 loop/
ground start trunks, this option
must be set to 1 for the trunks
to ring and light correctly.
0 = Normal/delayed
1 = Immediate Ringing
0
03 Flash Type
This option selects the flash
type (open loop flash or
ground). Always set this option
for open loop flash.
0 = Open Loop Flash
1 = Ground
0
04 Hooking Type
This option lets you use Flash
for Timed Flash (Program 81-
01-14) or Disconnect (Program
81-01-15). (A user implements
Flash by pressing the FLASH
key while on a trunk call.)
0 = Timed Flash (Hooking)
1 = Disconnect (Cut)
1 (SL1000)
0 (SL1100)
81-01-14
81-01-15
05 Dial Tone Detection for Manu-
ally Accessed Trunks
Use this option enable/disable
dial tone detection for directly
accessed trunks. If disabled,
the system outdials on the
trunks without monitoring for
dial tone.
0 = Dial Tone Detection
Not Used
1 = Dial Tone Detection
Used
1 21-01-04
06 Pause at 1st Digit after Line
Seize in Manual Dial Mode
0 = No Pause (No)
1 = Pause (Yes)
1 21-01-06
ISSUE 1.0 SL1000/SL1100
Program