Program 21 : Outgoing Call Setup
21-06 : Toll Restriction Table Data Setup
Level
IN
Description
Use Program 21-06 : Toll Restriction Table Data Setup to set the system Toll Restriction data. Dial 1
~9,0,
*
, # can be entered in each table.
Input Data
Item No.
Item Table Input Data Default
01 International Call Restriction Table
This option lets you program the Restrict
Table for international calls.
The system has 10 International Call Re-
strict Tables.
Each entry can have up to four digits.
1~10 Dial
(Up to four digits)
Tables1~10=Noset-
ting
02 International Call Permit Code Table
This option lets you program the Permit
Table for international calls.
The system has 20 International Call Per-
mit Tables.
Each entry can have up to six digits.
1~20 Dial
(Up to six digits)
Tables1~20=Noset-
ting
03 Maximum Number Digits Table Assign-
ment
This option selects the maximum number
of digits allowed in outgoing calls for each
table.
1~4 4~30 Tables1~4=30
04 Common Permit Code Table
This option lets you program the Common
Permit Code Table.
This table contains up to 10 codes you
commonly allow users to dial.
1~10 Dial
(Up to four digits)
Tables1~10=Noset-
ting
05 Common Restriction Table
This option lets you program the Common
Restrict Code Table.
This table contains up to 10 codes you
commonly prevent users from dialing.
1~10 Dial
(Up to 12 digits)
No setting
06 Permit Code Table
This option lets you program the Permit
Code Tables.
If the system has Toll Restriction enabled,
users can dial numbers only if permitted by
these tables and the Common Permit Table
(21-06-04).
There are four Permit Code Tables, with up
to 200 entries in each table.
The system permits calls exactly as you
enter the code.
1 ~ 4 (table)
001 ~ 200 (Entry)
Dial
(Up to 12 digits)
Tables1~4=Nosetting
07 Deny Restriction Table
This option lets you program the Restrict
Code Tables.
If the system has Toll Restriction enabled,
users cannot dial numbers listed in these
tables.
There are four Restrict Code Tables, with
up to 60 entries in each table.
The system restricts calls exactly as you
enter the code.
1 ~ 4 (table)
1 ~ 60 (Entry)
Dial
(Up to 12 digits)
Tables1~4=Nosetting