Program 80 : Basic Hardware Setup for System
80-07 : Call Progress Tone Detector Frequency Setup
Level
IN
Description
Use Program 80-07 : Call Progress Tone Detector Frequency Setup to set the frequency of the
detection tone set with Program 80-04-12 and Program 80-04-13.
Input Data
Frequency Table Number 1 ~ 8
Frequency
Table No.
Input Data Default
1 0,10~255
(100 ~ 2550 Hz)
(0 = Not used)
40 (400 Hz)
2 0
3 0
4 0
5 0
6 0
7 0
8 0
Conditions
None
Feature Cross Reference
None