Program 82 : Basic Hardware Setup for
Extension
82-04 : ASTU Initial Data Setup
Level
IN
Description
Use Program 82-04 : ASTU Initial Data Setup to set the basic data of the SLT.
Input Data
Item No. Item Input Data Default
01 Companding Method Type 0 = μ-law
1 = A-law
1
02 Ringing Frequency 0=25Hz
1=20Hz
2=16Hz
0 (25 Hz)
03 Minimum Break Time 1 ~ 255 (5 ms ~ 1275 ms) 2 (10 ms)
04 Maximum Break Time 1 ~ 255 (5 ms ~ 1275 ms) 20 (100 ms)
05 Minimum Make Time 1 ~ 255 (5 ms ~ 1275 ms) 2 (10 ms)
06 Maximum Make Time 1 ~ 255 (5 ms ~ 1275 ms) 20 (100 ms)
07 Minimum Hook Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 108 (540 msec)
08 Maximum Hook Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 132 (660 msec)
09 Minimum Ground Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)
10 Minimum Off-Hook Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)
11 No Detection Time after Off-Hook 1 ~ 255 (5 ms ~ 1275 ms) 60 (300 ms)
12 No Detection Time after Pulse Dial Detec-
tion
1 ~ 255 (5 ms ~ 1275 ms) 70 (350 ms)
13 Loop Disconnect Time, Reversal Time 1 ~ 255 (10 ms ~ 2550 ms) 60 (600 ms)
14 Ring, Message Wait Period Time 1 ~ 255 (5 ms ~ 1275 ms) 150 (750 ms)
Conditions
None
Feature Cross Reference
None
ISSUE 1.0SL1000/SL1100
Program
82
Program 82 : Basic Hardware Setup for Extension2-456