Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Level
IN
Description
Use Program 34-01 : E&M Tie Line Basic Setup to define the basic settings for each E&M Tie line.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Item
No.
Item Input Data Default Description
Related Pro-
gram
01 DID/E&M Start
Signaling
0=2
nd
Dial Tone
1=Wink
2 = Immediate
3 = Delay
0 Set the start signaling mode
for DID and Tie trunks. DID
and Tie trunks can use either
immediate start or wink start
signaling.
22-02
02 Receive Dial Type
for E&M Tie Line
0=DP
1 = DTMF
1 10-09
03 E&M Dial-In Mode 0 = Specify Extension
Number (Intercom)
1 = Use Conversion Table
(NTT)
0 Determine if the incoming Tie
Line call should be directed as
anintercomcallorifitshould
follow the DID Translation
Table in Program 22-11.
22-11
04 E&M Line Dial Tone 0 = Disable (No)
1 = Enable (Yes)
1 Enter 1 if the Tie Line should
send dial tone to the calling
system after the call is set up.
Enter 0 if the Tie Line should
not send dial tone.
05 System Toll
Restriction
0 = System
1 = Each Extension
0 Determine if an incoming Tie
Line call should be subject to
Toll Restriction. If it is set to 0
then it will use the Program
21-05-13, if it is set to 1 then it
will used Programs 21-05-01
~ 21-05-13.
21-05
Conditions
None
Feature Cross Reference
None
ISSUE 1.0 SL1000/SL1100