Program 80 : Basic Hardware Setup for System
80-11 : MFC Tone Receiver Setup
Level
IN
Description
Use Program 80-11 : MFC Tone Receiver Setup to various data for the MFC signal detection.
Input Data
MFC Tone Receiver Type Number 1 = MFC Receiver for Extension
2 = MFC Receiver for Trunk
3 = Reserved
4 = Reserved
5 = Reserved
Item No. Item Input Data
01 Detect Level 0=0dBm~-25dBm
1=-5dBm~-30dBm
2=-10dBm~-35dBm
3=-15dBm~-40dBm
4=-20dBm~-45dBm
5=-25dBm~-50dBm
6=-30dBm~-55dBm
02 Start delay time 0~255(0.25step,0ms~64ms)
03 Min. detect level 0~15
detectlevel0=-10dBm(0)~-25dBm(15)
detectlevel1=-15dBm(0)~-30dBm(15)
detectlevel2=-20dBm(0)~-35dBm(15)
detectlevel3=-25dBm(0)~-40dBm(15)
detectlevel4=-30dBm(0)~-45dBm(15)
detectlevel5=-35dBm(0)~-50dBm(15)
detectlevel6=-40dBm(0)~-55dBm(15)
04 Max. detect level 0~15
detectlevel0=0dBm(0)~-15dBm(15)
detectlevel1=-5dBm(0)~-20dBm(15)
detectlevel2=-10dBm(0)~-25dBm(15)
detectlevel3=-15dBm(0)~-30dBm(15)
detectlevel4=-20dBm(0)~-35dBm(15)
detectlevel5=-25dBm(0)~-40dBm(15)
detectlevel6=-30dBm(0)~-45dBm(15)
05 Twist level 0~9(1dB~10dB)
06 S/N ratio 0~4(-5step,0dB~-20dB)
07 ON detect time 1 ~ 255 (15 step, 30 ms ~ 3840 ms)
08 OFF detect time 1 ~ 255 (15 step, 30 ms ~ 3840 ms)
Table 2-17 Default Table
Item Name Type 1 Type 2 Type 3 Type 4 Type 5
01 Detect Level 00000
02 Start delay time 00000
03 Min. detect level 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm)
04 Max. detect level 0 (0 dBm) 0 (0 dBm) 0 (0 dBm) 0 (0 dBm) 0 (0 dBm)
05 Twist level 9 (10 dBm) 9 (10 dBm) 9 (10 dBm) 9 (10 dBm) 9 (10 dBm)
06 S/N ratio 2 (0 dBm) 2 (0 dBm) 2 (0 dBm) 2 (0 dBm) 2 (0 dBm)
ISSUE 1.0 SL1000/SL1100