Program 21 : Outgoing Call Setup
21-08 : Repeat Dial Setup
Level
IN
Description
Use Program 21-08 : Repeat Dial Setup to define the automatic Repeat Dial data.
Input Data
Item No. Item Input Data Default
01 Repeat Redial Count
Sets how many times a Repeat Redial auto-
matically repeats if the call does not go
through.
0 ~ 255 3
02 Repeat Redial Interval Time
Set the time between Repeat Redial attempts.
0 ~ 64800 seconds 60 seconds
03 Repeat Dial Calling Timer
After dialing the trunk call, Repeat Redial
maintains the call after this time. After this
time, the system terminates the call, waits the
Repeat Redial Time (Timer 02) and tries
again.
0 ~ 64800 seconds 30 seconds
04 Time for Send Busy Tone for ISDN Trunk
Sets the time (sec) to send out Busy Tone
with an ISDN line, when called party is busy.
0 ~ 64800 seconds 0 second
Conditions
None
Feature Cross Reference
None
ISSUE 1.0SL1000/SL1100
Program
21
Program 21 : Outgoing Call Setup2-228