Program 90 : Maintenance Program
90-67 : Backup Data Auto-save Interval Time Set
Level
IN
Description
Use Program 90-67 : Backup Data Auto-save Interval Time Set to set time interval D-RAM data that
is saved in F-ROM memory.
D-RAM memory : Configuration information such as call transfer and Do Not Disturb.
Input Data
Item No. Item Input Data Default This Program is ..
01 Interval time 0 ~ 255 48 (24 hr) 0 = Do not Auto-save
1=30min
2=60min
3=90min
:
255 = 30 min (127 hr)
Conditions
None
Feature Cross Reference
None
ISSUE 1.0 SL1000/SL1100
Program
90
Programming Manual 2-575