Program 90 : Maintenance Program
90-09 : Automatic System Reset Time Setup
Level
IN
Description
Use Program 90-09 : Automatic System Reset Time Setup to define the time for the system to auto-
matically reset.
Input Data
Item No. Item Input Data Default
01 Month
00~12
If the Month is set to 00 and Day
is set, the system is automatically
reset every month on the pre-
defined day.
00
02 Day
00~31
If the Day is set to 00 and the
Time (Hour and Minute) is set,
the system automatically resets
every day at the predefined time.
00
03 Hour 00~23 00
04 Minute 00~59 00
Conditions
None
Feature Cross Reference
None