Program 10 : System Configuration Setup
10-26 : IP System Operation Setup
Level
IN
Description
Use Program 10-26 : IP System Operation Setup to enable or disable the Peer to Peer feature for
SIP MLT and SIP IP stations.
Input Data
Item No. Item Input Data Default Note
02 RTP Forwarding Mode 0=Disable
1=Enable
0
03 SIP Peer to Peer Mode 0=Off
1=On
1
04 DR700 Peer to Peer Mode 0=Off
1=On
1
05 SIP CTI Mode
When SIP CTI Mode is set as 1 (Mode1)
it will ignore the setting at 10-26-03.
0=Disable
1 = Mode1
0
Conditions
Disabling 10-26-04 results in SIP MLT Station-to-SIP MLT Station calls using a DSP resource.
SIP-to-SIP MLT Station does not support Peer to Peer function and will result in using a DSP re-
source.
Disabling 10-26-03 results in SIP IP Station-to-SIP IP Station calls using a DSP resource.
Feature Cross Reference
None